Product Specifications
Category
|
EXTREmer |
Competitor |
| LENGTH |
60-200 mer |
45-200 mer |
| ERROR RATE (QUALITY METRIC) |
≤ 0.1, typically in the 0.050% - 0.066% range, or 1/1500 – 1/2000 |
≥ 0.1% - typically in the 0.100% – 0.125% range, or 1/800 – 1/1000 |
| FORMAT |
Tubes and Plates |
Tubes and Plates |
QUALITY CONTROL
|
Yes |
Yes |
| PURIFICATION OPTIONS |
Saltfree, PAGE, and HPLC |
Saltfree & PAGE |
Pricing
| Delivered Yield |
Format |
EXTREmer Price |
Competitor Price |
Order |
4 nmole yield saltfree
|
Tubes |
$0.95/base |
$0.99/base |
Order |
| Plates |
$0.50/base |
$0.53/base |
Order |
25 nmole saltfree, 1 nmole HPLC/PAGE purified
|
Tubes |
$1.95/base |
$2.03/base |
Order |
| Plates |
$1.05/base |
$1.11/base |
Order |
*Unmodified, unpurified EXTREmer oligos will have a minimum yield of 4 or 25 nmole respectively. Purified and/or modified EXTREmer oligos have a lower minimum yield as shown above.
Modifications
| Modification |
Designator |
5′ End |
Internal Positions |
3′ End |
Price/modification |
| Phosphate |
[PHO] |
✔ |
✖ |
✖ |
$30.25 |
| Biotin |
[BIO] |
✔ |
✖ |
✖ |
$50.00 |
| Amino C6 |
[AmC6] |
✔ |
✖ |
✖ |
$15.00 |
| Amino C12 |
[AmC12] |
✔ |
✖ |
✖ |
$75.00 |
| DeoxyInosine |
[I] |
✔ |
✔ |
✖ |
$9.00 |
| DeoxyUridine |
[U] |
✔ |
✔ |
✖ |
$9.00 |
*CGE = Capillary gel electrophoresis; ESI-MS = Electrospray ionization – mass spectrometry
High GC Percentage? No Problem
Our EXTREmer synthesis platform allows for the synthesis of DNA oligonucleotides even with very low sequence variation. The sequence,
CGG GGG CAG CGT GGA CGG GGG GCT GGG GAT GGG CGG GGT GGG GGC GGA GGG CGC GGG CGG CGG GCA GTG GGG GGC GGG CGG CGG GGG GGT GTA GAT CGG GGC GGG CGG G,
a 109-mer with 87% GC content, synthesized using our oligo synthesis platform is one example of such sequences. The ability to synthesize such oligos enables us to assemble genes or GeneStrands gene fragments with stretches of low sequence variation.
Technology
Our proprietary reagent handling systems facilitate the coupling of phosphoramidites with extremely high efficiencies resulting in oligos with extremely low sequence errors, which in combination with the extremely mild post-synthesis work up, allows us to synthesize extremely long oligonucleotides (from 60 to 200 bases), which we call EXTREmers.
EXTREmers are suitable for use in several molecular biology applications that require oligonucleotides with high sequence accuracy. These include:
- Cloning, de-novo gene synthesis, and site-directed mutagenesis involving introduction of large-scale insertions or deletions
- In the assembly of linear ds-DNA gene fragments, such as GeneStrands, for use with CRISPR/Cas systems
- Use as templates for in vitro transcriptions towards the generation of tRNA, shRNA, or other RNA molecules
- Use as a capture probe—a single EXTREmer oligo can contain mulitple functional segments of sequences with desired features
- As control standards in qPCR experiments
- Applications involving DNA-directed RNA interference (ddRNAi) experiments after cloning the same into appropriate expression vectors
- Other molecular biology experiments that require long oligo with high sequence accuracy.
These long oligos can help save a great deal of time and resources traditionally spent by researchers on ligating and assembling the desired oligo.
The desalted EXTREmers are dried down and can be delivered either in Tubes or 96-well Plates, as desired. The quality of these EXTREmers is assessed using either ESI-MS or capillary gel electrophoresis (CGE). Please note that while ESI-MS and CGE are good indicators of the quality of any oligo, the sequence errors introduced in the oligo during and post-synthesis are best evaluated by sequencing genes assembled using these oligos.
Error-rate and Cloning (con'd)
Error-rate is important in gene synthesis. Genes are now more frequently assembled using chemically synthesized, overlapping oligonucleotides. The overlapping oligonucleotides are ligated, extended, or 'filled' to create larger constructs or even genomes. Owing to mistakes in chemical synthesis and subsequent enzyme-based assembly processes, the assembled genes unavoidably contain errors. The average rate of the errors attributed to chemical synthesis typically range from 1 to 10 errors per kilobase pair of assembled DNA. The following graph on the left displays the theoretical probability of finding an error-free gene of different lengths at a given error rate.
After gene assembly, cloning and subsequent sequencing of the isolated DNA from multiple clones allows a researcher to identify the clone(s) with the correct sequence. The number of clones that need to be sequenced to identify the one perfect clone also depends on the error rate; the graph on the right displays the number of clones that need to be sequenced (at 95% confidence level) before the 'one' is found. Clearly, the number of clones that need to be sequenced is fewer when the clones are assembled using the lower error rate oligos.
Error Correction
Some companies employ error-correction technology to further reduce the error rate of oligos. Although Eurofins Genomics does not utilize error-correction technology due to the naturally low error rates of its raw product, customers could apply such technology to further enhance the performance of EXTREmer oligos in cloning applications. Several enzyme-based error-removal methods have been developed to mitigate the propagation of synthesis errors incorporated during chip- and array-based synthesis. These error-removal methods essentially use enzymes to enrich the pool of the oligos with the desired oligos by selectively removing the 'undesired' oligos. The error-removal methods can be readily simplified when oligos with low error-rate are used in the initial assembly of the genes.
Process
EXTREmers, much like the other chemically synthesized oligonucleotides at our Oligo synthesis facility, are subjected to the conventional QC processes, i.e., mass spectrometry (and/or electrophoresis in case of EXTREmers), before being shipped to you. We are, however, aware that the MS- and Chromatography-based analytical techniques do not provide sufficient information about the sequence of the chemically synthesized oligonucleotides. The mass spectra of ACGGAGA is indistiguishable from that of ACGAGGA. Therefore, in a representative study, we used EXTREmer oligos in cloning and subsequent sequencing experiments to evaluate the sequence-errors present in the synthesized EXTREmer and the propagation of these errors during the gene assembly and cloning process.
| Length of Gene (bp) |
GC% |
Good Clones (%) |
Total kbp Sequenced |
Number of Seq. Errors |
Error Rate (%) |
| 617 |
65 |
45 of 64 (70%) |
39.488 |
21 |
0.05% |
| 1,020 |
41 |
10 of 20 (50%) |
20.400 |
11 |
0.05%
|
| 1,286 |
40 |
34 of 48 (71%) |
56.922 |
20 |
0.03% |
| 1,520 |
44 |
17 of 31 (55%) |
47.120 |
19 |
0.04% |
| 1,791 |
44 |
4 of 18 (22%) |
32.238 |
28 |
0.09% |
| 1,869 |
52 |
3 of 8 (38%) |
14.952 |
7 |
0.05% |
| 1,890 |
51 |
6 of 15 (40%) |
28.350 |
14 |
0.05% |
| 1,947 |
52 |
5 of 11 (45%) |
21.417 |
10 |
0.05% |
Genes of different sizes and GC contents were assembled using EXTREmer oligos. The sequences of the resulting genes were read either using the Sanger method or Next-Gen Sequencing methods. The graphs above display the Cloning Efficiency (A) and the error rates (B). Sequencing errors include insertions, deletions, and substitutions. No error-removal methods were employed during the assembly of these genes.
In summary, these results indicate that nearly 50% of the clones harbor a DNA of the correct size and 1 error is observed for a sequence lenght of 2,000 bp (the sequencing errors are further reduced when error-removal methods are used during gene assembly).
What do these results mean for your experiments? You will have to select fewer colonies during your cloning experiments and the likelihood of the sequence of the isolated DNA being the desired sequence is high! These features save you both time and money (used for the reagents and conducting the various molecular biology experiments).
Morever, our studies reveal that the number of sequence errors does not vary significantly based on the GC content of the assembled target sequence. The genes in the study below were assembled using PCR assembly with high-fidelity enzymes. Subsequently, error removal methods were used.
Effect of GC content on the errors (1500 bp gene)
| GC content (%) |
Error rate (%) |
Total kbp Sequenced |
| 30 |
0.0025 |
16.236 |
| 45 |
0.0038 |
13.284 |
| 60 |
0.0055 |
16.236 |
| 70 |
0.0041 |
14.760 |
| Average |
0.0040 |
60.516 |
Please note that Genes and GeneStrands prepared at our Louisville gene synthesis labs are assembled using EXTREmers. Both these products are synthesized using low-yield, high-fidelity chemical synthesis protocols and therefore yield oligonucleotide products with very low-sequence errors.
How to Order
Order Tubes
Order Plates